GE Marquette EKG
Manufacture Part No. MAC1200
Condition: Previously utilized in a clinical setting in Great Shape
Technician Notes: Mac 1200 ECG read out is accurate but there are some light spots on the print out. Unit is still highly useful, Likely needs a new battery
All Pre-Owned and Refurbished Equipment Undergoes Biomedical Certification and Inspection to Ensure Proper Functionality. This assessment Does Not Cover Cosmetic Defects. If No Defects are Mentioned in the Above Condition (Defects Include Scuffing of the Paint, Rusting or Tears) the Unit is Free from Any Flaws
Features
- Full-Size Keyboard is Easy to Use and Clean
- Large Backlit, Waveform LCD Display Has Contrasted Adjustable
- Integrated Thermal Printer for Full-Size Paper Reports
- Display Options
- Elected Lead Groups
- Operation Mode
- Lead Check
- Heart Rate
- AC Filter
- Muscle Her
- ADS Gain Speed
- Patient Information
- Elected Lead Groups
- Built-In Rechargeable Battery
- Anti Drift System (ADS) Automatically Compensates for the Baseline Fluctuations that are Caused by Polarization Voltage Fluctuations at the Electrodes
- Baseline Adjust Where the ECG Presentation is Shown with an Average Baseline
- Electrode Monitoring Where there is an Audible and Visual Indication on the LCD of Disconnected Electrodes or Fine Break
- Automatic Performance Test Upon Power Up, Including Verification of the Signal Path Starting at the Signal Input
Specifications
- Dimensions: 14.5"W x 3.7"H x 12.6"D
- Signal Processing
- Acquisition: 12 Leads - Simultaneously
- Signal Input: Type CF According to IEC
- Digital Sampling Rate: 1000 Samples/Second/Channel
- Dynamic Range: Differential Signals for AC Voltage, 10mV Superimposed DC Voltage (Polarization Voltage) 600mV
- Resolution: 5 uV
- Frequency Response: .04 - 150 Hz
- Common Mode Rejection: > 140 dB
- Input Impedance: > 100 M ohms
- Leakage Current: < 10uA
- Pacemaker Detection Sensitivity: All Leads, Duration 0.1 - 2.5 ms, Amplitude > 5mV
- Display
- Type: LCD 320 x 240 Pixels, Backlit, Contrast Adjustable
- Displayed Data: Selected Lead Group, Operation Mode, Lead Check, Heart Rate, AC Filter, Muscle Her, ADS Gain, Speed, Name, ID, 3 ECG Wave forms
- Writer
- Type: Thermal-Array Print Head
- Resolution: Vertically 8 Dots/mm Horizontally 25um at 25 mm/s
- Paper: 8.5 x 11 Inch
- Writer Speed: 5, 25, 50 mm/s
- Paper Type: Z-Fold
- Keyboard
- Type: Membrane Keypad with Tactile Feedback / 46 Keys
- Type: Membrane Keypad with Tactile Feedback / 46 Keys
- Special Functions
- Anti Drift System (ADS): Automatic Compensation of Baseline Fluctuations Caused by Polarization Voltage Fluctuations at the Electrodes
- Baseline Adjustment: ECG Presentation on the Averaged Baseline
- Electrode Monitoring: Audible and Visual Indication of Disconnected Electrodes or Fine Break on the LCD. Every Electrode is Monitored
- Copy: In the Automatic 12 Leads Modes, After the ECG, Recording, Copies of the ECG Can be Printed
- Test: Automatic Performance Test Upon Power Up, Including Verification of the Signal Path Starting at The Signal Input
- Power Supply
- Rating: 10 - 120 V / 220 - 240 V
- Frequency: 49 - 65 Hz
- Battery Type: NiCad. 18V, 1.4, Ah
- Battery Charge Time: 4 Hours